The Modbus TCP Server is a simple, in python written, Modbus TCP server. The Modbus registers can be also predefined with values.
The Modbus server was initially created to act as a Modbus slave mock system for enhanced tests with modbus masters and to test collecting values from different registers.
The Modbus specification can be found here: PDF
Step - 1 : Pull the Modbus TCP Server
docker pull jforge/modbus-serverStep - 2 : Run the Modbus TCP Server
docker run --rm -p 5020:5020 jforge/modbus-server:latestStep - 3 : Predefine registers
The default configuration file is configured to initialize every register with a 0x0000.
To set register values, you need to create your own configuration file.
docker run --rm -p 5020:5020 -v ./server_config.json:/server_config.json jforge/modbus-server:latest -f /server_config.jsonor you mount the config file over the default file, then you can skip the file parameter:
docker run --rm -p 5020:5020 -v ./server_config.json:/app/modbus_server.json jforge/modbus-server:latestThe path and filename to the general configuration file can be set via command option -f <file> after mounting it inside of the container. By default, the script will use /app/modbus_server.json.
The /app/modbus_server.json file comes with following content:
{
"server": {
"listenerAddress": "0.0.0.0",
"listenerPort": 5020,
"tlsParams": {
"description": "path to certificate and private key to enable tls",
"privateKey": null,
"certificate": null
},
"logging": {
"format": "%(asctime)-15s %(threadName)-15s %(levelname)-8s %(module)-15s:%(lineno)-8s %(message)s",
"logLevel": "INFO"
}
},
"registers": {
"description": "initial values for the register types",
"zeroMode": false,
"initializeUndefinedRegisters": true,
"discreteInput": {},
"coils": {},
"holdingRegister": {},
"inputRegister": {}
}
}| Field | Type | Description |
|---|---|---|
server |
Object | Modbus slave specific runtime parameters. |
server.listenerAddress |
String | The IPv4 Address to bound to when starting the server. "0.0.0.0" let the server listens on all interface addresses. |
server.listenerPort |
Integer | The TCP port number of the modbus slave to listen to. |
server.tlsParams |
Object | Configuration parameters to use TLS encrypted modbus tcp slave. (untested) |
server.tlsParams.description |
String | No configuration option, just a description of the parameters. |
server.tlsParams.privateKey |
String | Filesystem path of the private key to use for a TLS encrypted communication. |
server.tlsParams.certificate |
String | Filesystem path of the TLS certificate to use for a TLS encrypted communication. |
server.logging |
Object | Log specific configuration. |
server.logging.format |
String | The format of the log messages as described here: https://docs.python.org/3/library/logging.html#logrecord-attributes |
server.logging.logLevel |
String | Defines the maximum level of severity to log to std out. Possible values are DEBUG, INFO, WARN and ERROR. |
registers |
Object | Configuration parameters to predefine registers. |
registers.description |
String | No configuration option, just a description of the parameters. |
registers.zeroMode |
Boolean | By default the modbus registers starts at 1 (false) but some implementation requires to start at 0 (true). |
registers.initializeUndefinedRegisters |
Boolean | If true the server will initialize all not defined registers with a default value of 0. |
registers.discreteInput |
Object | The pre-defined registers of the register type "Discrete Input". |
registers.coils |
Object | The pre-defined registers of the register type "Coils". |
registers.holdingRegister |
Object | The pre-defined registers of the register type "Holding Registers". |
registers.inputRegister |
Object | The pre-defined registers of the register type "Input Registers". |
Pre-define registers always starts with the register number. We use a json format as configuration file, so the "key" needs to be a string. So, the register number needs also to be a string. During server initialization, the json key that represents the register number will be converted to an integer.
As by the modbus spec, the "Discrete Input" and "Coils" registers contains a single bit. In the json configuration file, we use true or false as register values.
Example configuration of pre-defined registers from type "Discrete Input" or "Coils":
[..]
"<register_type>": {
"0": true,
"1": true,
"42": true,
"166": false
}
[..]
As by the modbus spec, the "Holding Registers" and "Input Registers" tables contains a 16-bit word. In the json configuration file, we use a hexadecimal notation, starting with 0x, as register values.
Example configuration of pre-defined registers from type "Holding Registers" or "Input Registers":
[..]
"<register_type>": {
"9": "0xAA00",
"23": "0xBB11",
"142": "0x1FC3",
"2346": "0x00FF"
}
[..]
version: '3.8'
services:
modbus-server:
container_name: modbus-server
image: jforge/modbus-server:latest
restart: always
command: -f /server_config.json
ports:
- 5020:5020
volumes:
- ./server.json:/server_config.json:ro